Charge Pump PLL IP

Description

This Charge Pump PLL is designed in CMOS LP technology, using seven metallization levels. These voltage pulses are converted to current pulses in the Charge Pump. These current pulses charge or discharge the Loop Filter to generate the control voltage for the VCO. The VCO generates a frequency (FVCO) proportional to this control voltage. This frequency is then divided by the Loop Frequency Divider, to generate FBCLK. 1467182555pll_300

Features

    • Input frequency (MHz): 19.2-40MHz
    • VCO frequency: 1500-3000MHz
    • Output frequency: PHI: 23.4375-1500MHz
    • Uses LVT and SVT devices in GO1 and SVT25 devices in GO2
    • Area: 0.1788 mm2 (Target) (X = 208 m, Y =860 m)
    • Maximum power: 15.22 mW
    • Fractional mode supported
Seven metal level technology used for design:
    • 4X (thin) metals
    • 0Y (intermediate) metals
    • 2Z (thick) metals

Applications

    • Used in frequency synthesis applications

Deliverables

  • Detailed Specification and Integration guide
  • LEF abstract
  • GDSII layout and Mapping files
  • LVS compatible netlist
  • Verilog-A Model